Diesel
Standard diesel fuel (#2 diesel, heating oil, red diesel).
All temperatures are measured at the heat exchanger (exterior of burn chamber). For burn cycle behavior, see Burn Cycle.
Temperature Thresholds
Threshold |
Temperature |
Purpose |
|---|---|---|
Combustion establishing |
190°C |
Transition to leaner mixture |
Combustion stable |
200°C |
Glow plug off, PID controller on |
Normal operation |
215°C |
PID target temperature |
Pump reduction |
230°C |
Reduce pump rate by 50% |
Pump recovery |
210°C |
Restore normal pump rate |
Pump disable |
250°C |
Disable pump until below threshold |
Flame-out detection |
190°C |
Combustion failure |
Cooldown glow start |
180°C |
Begin carbon burnoff |
Cooldown complete |
120°C |
Glow plug extinguishes, fan cooldown timer starts |
Emergency stop |
275°C |
Component protection |
Timing and Settings
Parameter |
Value |
Notes |
|---|---|---|
Glow plug warmup |
60 seconds |
Time before fuel injection |
Ignition timeout |
5 minutes |
Maximum time to reach combustion |
Ignition pump rate |
500ms |
Rich mixture for ignition |
Preheating pump rate |
250ms |
Leaner mixture for stable burn |
Maximum pump rate |
5000ms |
Slowest fuel delivery (validation limit) |
Ignition RPM |
2500 |
Initial airflow |
Preheating RPM |
2800 |
Increased airflow |
Cooldown RPM |
2500 |
Heat dissipation |
Fan cooldown timer |
5 minutes |
Run after glow plug extinguishes |